Ssl ii with asj max fiberglas pipe insulation.
Chilled water pipe insulation specifications.
When piping and equipment.
Insulating chilled water systems requires special attention.
No wrap pipe.
Proper installation and maintenance will prevent the design from being compromised.
We have the 3 part jm insul spec which is a complete fiber glass chilled water specification.
Now offering larger 8 and 10 ids for ease of installation on larger pipe sizes.
2 0 role of pipe insulation for chilled water systems 33 f to 60 f 0 5 c to 15 6 c pipe insulation for chilled water systems is specified and installed primarily for process control condensation control and energy conservation.
It is the ideal choice for insulating mechanical piping systems.
Proper insulation of chilled water pipe systems.
3 3 1 2 if insulation is unavailable in thickness shown the next larger thickness commercially available shall be applied.
Jm can help with the specification as well.
What sets pipe insulation products apart from other forms of thermal insulation such as blankets boards sheets and block is that pipe insulation is usually pre formed into standardized pipe dimension.
Exchangers machinery ect and piping which are to be insulated in accordance with the specifications.
Ap armaflex the world s most recognized brand of closed cell foam insulation provides superior protection against thermal losses condensation and moisture accumulation that leads to mold.
Chilled water systems from 35f 2c to 65f 18c heating systems steam steam condensate hot water ambient up to 450f 232c.
Fiberglass pipe insulation on all chilled water and dual cycle pipe systems fittings valves controls and all other necessary items connected into the system subject to condensation or loss of heat when using jm micro lok fiberglass pipe insulation.
Owens corning ssl ii with asj max fiberglas pipe insulation is molded out of heavy density resin bonded inorganic glass fiberglas that come in one piece 36 914mm long hinged sections.
06 01 2012 by christopher curtland faulty design installation or maintenance can cause disaster with chilled water systems selecting the correct materials for the jacket and retarder ensures the pipe is protected.
Insulation materials and accessories shall be installed in a workmanlike manner by skilled and experienced workers who are regularly engaged in commercial insulation work.
We can also personally review your specification and provide feedback.
Astm c547 specification for mineral fiber pipe insulation.
Naima s guide to insulating chilled water systems offers detailed instructions on performance installation and required specifications.
Naima also has a chilled water insulation guide that has information on writing a chilled water specification.